30
Specifications
\
Impedance 50 ohms nominal
Insertion VSWR
With “N” Connectors 1.05 Max. to 1000 MHz, 1.1 Max. to 2300
MHz
Connectors Bird Quick Change “QC” Female N
normally supplied‘
RF Power Ranges
Average (CW) Mode
Peak-pulse or envelope-power
mode
100 mW to 10 kilowatts ( 5% of full scale)
100 mW to 10 kilowatts ( 8% of full scale)
Frequency Range 0.45 to 2700 MHz (either mode)
Pulse Parameters
Minimum duty factor
Minimum repetition rate
Minimum pulse width
1.0 x 10-4
30 pps
0.4 microseconds at 100-2300 MHz
1.5 microseconds at 26-99 MHz
15 microseconds at 2-25 MHz
Weight 3 lb. (1.4 kg)
Dimensions 3-5/8”L x 4”W x 7”H
(92.1 x 102 x 178 mm)
AC Power Requirements
(using adapter)
*
*. Use only adapter supplied by Bird Electronic Corporation
115 Vac. 10%, 60 Hz
220 Vac, 10%, 50Hz
Batteries Two 9 V alkaline
Battery Life 20 hours of operation, typically